SAE J1939 acquisition

(1) Open CommBridge Digital Twin and switch to Device Connectivity.

Open Device Connectivity

(2) Drag SAE J1939, Data Processing, and MQTT Upload into the workspace to create three nodes.

Create CAN acquisition nodes

(3) Connect the three nodes in this order: SAE J1939 → Data Processing → MQTT Upload.

Connect the CAN data flow

(1) Double-click SAE J1939 and select Add scheme.

Add a SAE J1939 scheme

(2) Enter connection settings, import a DBC file, and select Next.

SAE J1939 connection settings Import a DBC file

(3) Review group and point information.

Imported messages and signals

(4) Select Finish to add the acquisition scheme.

Complete the CAN scheme

(5) Enable the scheme and select Save.

Enable the CAN scheme

(1) Select Deploy under Device Connectivity and wait for success.

Deploy CAN acquisition

(2) Switch to Digital Twin and hover over SAE J1939 to display node information.

SAE J1939 node information

(3) Select a scheme to view real-time and historical point data in each group.

CAN acquisition results

Parameter Prerequisite Description Format Example Notes
Scheme name User-defined name for the scheme Nonempty CAN acquisition
CAN interface Actual CAN interface on the device Drop-down list vcan0
DBC See below DBC file testType.dbc
Name configuration method Hex Number
Preferred address Drop-down list 128
Returned data type Type of acquired real-time data Drop-down list Phy
Socketcand Whether to enable socketcand, which provides network access to the computer’s CAN interfaces Yes, No No
Socketcand port Used for remote data debugging Number
Name Preferred address is Hex Number A 64-bit (8-byte) Name that uniquely identifies each ECU 0x7758
Arbitrary address capable Preferred address is Properties Whether this ECU may automatically change its source address: 1 permits this, 0 fixes the address Number: 0, 1 0
Industry group Preferred address is Properties Industry category of the vehicle Number, range: [0,7] 0
Device class instance Preferred address is Properties Instance number distinguishing devices within the same class Number, range: [0,15] 0
Device class Preferred address is Properties SAE-defined 7-bit device/system classification Number, range: [0,127] 0
Function Preferred address is Properties Specific function performed by the ECU within the vehicle system Number, range: [0,255] 0
Function instance Preferred address is Properties Instance number distinguishing multiple ECUs performing the same function Number, range: [0,31] 0
ECU instance Preferred address is Properties Distinguishes instances of the same physical ECU model Number, range: [0,7] 0
Manufacturer code Preferred address is Properties SAE-assigned 11-bit manufacturer identifier Number, range: [0,2047] 0
Identity number Preferred address is Properties Manufacturer-defined 21-bit serial number Number, range: [0,2097151] 0

Note:

  1. DBC supplies the original data structure. Subsequent changes to groups (messages) and data (signals) are merged into this DBC structure.
  2. Raw returns raw values; Phy returns physical values; PhyWIthUnit returns physical values with units.
  3. Communication uses TCP/IP connections and a dedicated protocol to transmit CAN frames and control commands. Currently only Classical CAN is supported, not CAN FD.
  4. Preferred address: Hex Number, Properties.
  5. Two nodes on a J1939 network cannot use the same address. To avoid address conflicts, J1939 uses a 64-bit Name and an 8-bit Address together to identify a node. Name structure:
    1. Arbitrary address capable, 1 bit: 0 means the node’s address is statically configured by the network administrator; 1 means it is dynamically assigned at random.
    2. Industry group, 3 bits. Common values: 000 (global), 001 (on-highway vehicles, such as trucks and buses), 010 (agriculture), 011 (construction), etc.
    3. Vehicle system instance, 4 bits.
    4. Vehicle system, 7 bits.
    5. Reserved bit.
    6. Function, 8 bits.
    7. Function instance, 5 bits.
    8. ECU instance, 3 bits.
    9. Manufacturer code, 11 bits.
    10. Identity number, 21 bits.
Parameter Description Format Example
Group name User-defined group name Nonempty t_msg_1_unsigned
Message name Describes the message’s function or purpose Nonempty; letters, digits, and underscores only; cannot start with a digit t_msg_1_unsigned
Priority 3
Parameter group number 0x0
Data length code Data length code (DLC): Classical CAN DLC 0–8 corresponds to 0–8 bytes. CAN FD DLC 0–8 also corresponds to 0–8 bytes; DLC 9–15 corresponds to 12, 16, 20, 24, 32, 48, and 64 bytes respectively. These protocol length definitions do not imply that the current plugin supports CAN FD. Number, [0,8] or [0,15] 8
Transmitting node Transmitter: the node sending the message Dropdown, default Vector__XXX Vector__XXX
Message description Optional explanation of message function String

Note:

  1. A group corresponds to a Message in the DBC file.
  2. If no transmitter is specified for the message (group), use Vector__XXX.
Parameter Prerequisite Description Format Example
Signal name User-defined signal name describing its function
Suspect parameter number
Signal mode Signal transmission mode Dropdown
Start bit Zero-based signal starting position within the CAN frame Bits 0
Value type Signal data type Dropdown Intel
Byte order Signal storage order within the message Dropdown
Scaling factor Factor converting raw values to physical values Floating-point number
Offset Offset for physical value calculation Floating-point number
Minimum Minimum physical value limiting the signal range Floating-point number
Maximum Maximum physical value limiting the signal range Floating-point number
Unit Physical unit String
Receiving nodes One or more target nodes receiving the signal Dropdown, default Vector__XXX
Description Physical unit, such as km/h, °C, or m/s String
Calculation User-defined formula based on data aliases
Length Value type is Unsigned/Signed Number of bits occupied by the signal Bits, [1,64]
Multiplex value Signal mode is not Signal Multiplexor value at which this signal becomes active

Note:

  1. Signal modes: Signal, Multiplexor, Multiplexed.
  2. Value types: Unsigned, Signed, Float (single precision), Double (double precision).
  3. Byte order: Intel (little-endian) or Motorola (big-endian).
  4. Start bit: position of the least significant bit (LSB).
  5. End bit: position of the most significant bit (MSB).
  6. Resolution and offset convert physical and network values: network value = (physical value - offset) ÷ resolution.
  7. If no receiver is specified, use Vector__XXX.

A DBC (CAN Database File) is a standard format describing messages and signals on a Controller Area Network bus.

(1) Node

A node logically represents a network device and may transmit or receive messages.

1). DBC format:

BU_: Node1 Node2 Node3
  • BU_: defines the node list.
  • Node names follow, separated by spaces.

(2) Message

A message is the smallest transmitted data unit on the CAN network, containing multiple signals with a fixed ID and length.

1). DBC format:

BO_ <message-ID> <message-name>: <data-length-code> <transmitting-node>

2). Example:

BO_ 1001 SpeedMessage: 8 Node1
  • BO_: identifies a message.
  • 1001: message ID.
  • SpeedMessage: message name.
  • 8: data length code (DLC).
  • Node1: transmitting node.

(3) Signal

A signal is a data unit within a message representing a physical quantity such as speed, rotational speed, or temperature.

1). DBC format:

SG_ <signal-name> : <start-bit>|<length>@<byte-order><value-type-sign> (<scaling-factor>,<offset>) [<minimum>|<maximum>] "<unit>" <receiving-node>

2). Example:

SG_ Speed : 0|16@1+ (0.1,0) [0|200] "km/h" Node2
  • BO_: identifies a message.
  1. d
63 (MSB) 62-60 59-56 55-49 48 47-40 39-35 34-32 31-21 20-0 (LSB)
Arbitrary address capable Industry group Vehicle system instance Vehicle system Reserved Function Function instance ECU instance Manufacturer code Identity number
1 bit 3 bits 4 bits 7 bits 1 bit 8 bits 5 bits 3 bits 11 bits 21 bits
  1. Signal modes
Signal mode Meaning
Signal Ordinary signal carrying data directly without special markers or relationships
Multiplexor Selector signal determining which group of signals a message carries; for example, selects one of several data formats
Multiplexed Signal bound to a multiplexor; the multiplexor value determines whether it is transmitted, such as a particular group sent when the selector equals 1